<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-29 01-11-43
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 71 dBuV Classic
Pilot RDS Phase Difference
6.7 kHz 2.8 kHz -86 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 67 kHz 19000 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-1,2 dBr 1,44 dBr 3,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 1 (News) 1 0 1 1 --:--
RT
"Suomen suosituin klassisen musiikin kanava. "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 67 kHz MIN: 9 kHz % above 76 kHz: 0,0000 Acquired: 2025/01/29 1.10.40 Total samples: 19000 Equivalent time: 0:15:50 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 3,6 dBr MIN: -1,2 dBr AVE: 1,44 dBr % above 12,2 dBr: 0,0 Last value: 3,4 dBr (2025/01/29 1.10.39) 00.56 00.58 01.00 01.02 01.04 01.06 01.08 01.10 -2 0 2 4 Pm [dBr]